173
Forcing logical drives to come online
If the number of offline drives exceeds the tolerance range of the logical drive fault-tolerant method,
the management tool interface will display the logical drive state as Failed. In this case, you can
use the Force Online function to force the logical drives to come online. The Force Online function
for storage controllers is named Force Online LD in Legacy mode boot mode.
CAUTION:
•
Forcing a logical drive in Failed state to come online might cause the existing data on the
logical
drive to become invalid or unrecoverable. You can reformat and use the logical drive in the OS.
•
The Force Online operation might change data a logical
drive. Before performing this operation,
make sure you fully understand the impact.
To force logical drives to come online:
1. On the storage controller configuration screen as shown in Figure 273, for example,
RAID-P460-M2, select Array Configuration and press Enter.
Figure 273 Storage controller configuration screen
2. On the screen as shown in Figure 274 select Manage Arrays and press Enter.
Figure 274 Array Configuration screen
3. On the screen as shown in Figure 275, select an array that has failed due to offline drives and
press Enter.