EasyManua.ls Logo

Hach sc100 1720E - Setting up System Security

Hach sc100 1720E
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
31
4.4.1 Setting Up System Security
The sc100 has a passcode feature to restrict unauthorized access to Network
Setup, Security Setup, Log Setup, and Test/Maint menus. In addition, the
passcode also regulates function selection for relay options. The passcode is
factory set to sc100 (the five digits must be followed by a space to remove the
trailing asterisk). The passcode may be changed, see section 4.4.1.1.
The following two options are available:
Disabled: All configuration settings and calibrations can be changed. This is the
default setting.
Enabled: All configuration settings can be displayed but not changed. Network
Setup, Security Setup, Log Setup, and Test/Maint menus cannot be accessed
without the passcode.
4.4.1.1 Editing the Passcode
If the passcode is enabled, it may be edited. The passcode can consist of up to six
digits (alpha and/or numeric and available characters). If a passcode is forgotten,
obtain the Master passcode from the Technical Consulting Services Department,
see Technical and Customer Service (U.S.A. only) on page 57.
Step Select Menu Level/Instructions Confirm
1
MAIN MENU
2
SYSTEM SETUP
3
SECURITY SETUP
4
SET PASSCODE
5
highlight ENABLED
6
Main Menu or Main Measurement Screen
Step Select Menu Level/Instructions Confirm
1
MAIN MENU
2
SYSTEM SETUP
3
highlight SECURITY SETUP
4
ENTER (current or default) PASSCODE
EDIT PASSCODE

Table of Contents

Related product manuals