51
[Maintenance]
Ch_duration_1= 0:00:00
Cycles_1= 0
Ch_duration_2= 03:53:51
Cycles_2= 14
15.2.6. Maintenance
Field Possible value Note
Ch_duration_x H:M:S Total charging time of the socket x or x = 1 (T2S) or 2 (TE).
Cycles_x Integer Number of contactor opening and closing cycles x or x = 1 (T2S) or 2 (TE).
15.3. Log file
A Log file named “B1280 logs.csv” is written to the flash drive when it is inserted into the USB port of the controller board. This file informs the
installer about the saved charging sessions by providing various information during charging, such as:
1. The number of socket 1 (T2S) or 2 (TE)
2. The energy consumed during the charge
3. The time in seconds to session start
4. The time in seconds to session stop
5. The time in seconds to charging start
6. The time in seconds to charging stop
7. The session time in seconds
8. The charging time in seconds
9. The error code
As memory is limited, only the last session recordings are kept.