RE 15409, Version 08.2022, Bosch Rexroth AB
Technical data | CMp 35/64
6.3.6 Adapterange
Function
The ange of SAE 6000 type can be used to install temperature and/or pressure
sensors in the hydraulic system.
Fig. 33: Adapter ange, type 60, 61, 62, 63
A
B
Table 22: Dimensionsanges
Type Connection A B Max pressure
mm mm Bar
60 1" 25
G ¼" 400
61 1 ¼" 32
62 1 ½" 38
63 2" 51
DD00078682
DD00078683
6.3.7 Cable
Function
Cabel for in- and outdoor use. It can be used in areas where aggressive and
mineral oils occur and where the cable is exposed to high mechanical stress and
small bending radius. Individual numbering on each core.
Table 23: Electrical data, cable
Numbers of cores 5
Cross section area 0,5mm^2
Cable diameter 8,9mm
Rated voltage DIN VDE/IEC: 300/500 V
UL/CSA: 600 V
Insulation resistance min 100MOhm/km
Temperature range -40...85°C
Bending radius 7,5x cable diameter
Norms DIN VDE 0245, 0281
UL: Style 20234
CSA: AWM I A/B, II A/B, FT1