POSITIONING THE PHOTO EYE ASSEMBLY
The centering of the Label with the Bag is determined by the position of the Photo Eye.
1. Pull back on the Cam Lock to release the Photo Eye Assembly.
2. Compare the center of the Label with the center of the Bag. Measure the distance from the center of the
Label to the center of the bag. Slide the Photo Eye Assembly that same distance in either direction.
3. Secure the Photo Eye Assembly in that position by pushing down on the Cam Lock.
4. With the Mode Selector Switch in the Hand position, using the Jog Button cycle the machine several
times to see that the Label is centered with the Bag, if not repeat Steps #1 thru #3 as many times needed.
(Refer to "Adjustment" section, Photo Eye Detector).
POSITIONING THE PERFORATOR ASSEMBLY
1. Pull back on the Cam Lock to release the Perforator Assembly.
2. Slide the Perforator Assembly over to the Eye Mark that is closest to the Photo Eye Assembly. Position
the Blade of the Perforator approx. 1/2" from the leading edge of the Eye Mark as shown in (Figure 4).
3. Secure the Perforator Assembly in that position by pushing down on the Cam Lock.
(Refer to "Adjustments" section for Perforator Blade Adjustment and Replacement).