Rev.7 29
TROUBLESHOOTING GUIDE (CONTINUED)
Symptom Cause Correction
Volumetric dumps more
times then selected on the
four position switch. The
switch is set on two or
more dumps.
Sticking or slow clutch air
valve.
Adjust Prox Switch
Activating Cam.
Lubricate, clean, or replace the valve.
Replace Prox Switch Activating Cam.
Bag top perforations
breaking.
Perforation blade adjustment
is to deep.
Reduce the blade protrusion from the blade
mount.