MINIVATOR SIMPLICITY
+
INSTALLATION MANUAL 35
Appendix 3
Code: Meaning:
o Default Eeprom.
Description:
The Eeprom has been reset to its default value
(Flash Failure).
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
Code: Meaning:
P
P PS no reply.
Description:
Powered swivel did not respond.
Telephone fault finding action:
NOT YET ACTIVE.
On site fault finding action:
NOT YET ACTIVE.
Code: Meaning:
r No charge current.
Description:
Activated.
Telephone fault finding action:
Check that power supply is switched on from mains
supply. If yes send engineer.
On site fault finding action:
Check power supply.
Code: Meaning:
U
U No float indication V1.19
software and later only.
Description:
Faulty power supply.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace power supply.
Code: Meaning:
y Software error.
Description:
The main control board has a software fault.
Telephone fault finding action:
Send engineer.
On site fault finding action:
Replace main board.
Code: Meaning:
N/A Over current.
Description:
N/A.
Telephone fault finding action:
Send engineer with a service exchange power pack.
On site fault finding action:
Replace power pack.
Code: Meaning:
.8.
N/A Lift is in “sleep mode” to
conserve battery power.
Description:
Telephone fault finding action:
None.
On site fault finding action:
Press toggle or handset button to wake lift.
Note: If the display is showing
anything but the diagnostic codes
listed it requires resetting.
Drive the lift off the charge contacts.
Turn the main switch on the unit off
for 10 seconds and then back on.