42 | Pro‑Stcher Lite for the HQ Simply Sixteen www.ProStcher.com
Problem/Symptom Correcve Measure
Jumps between repeated paerns
Use of any of the Repeat opons results in a
jump between each paern
When using the Repeat funcons, if the start and/or
stop points are within the block of the paern (i.e. they
are not located at the le and right‑hand sides of the
paern block and/or not at the same height), there will
be a jump between each repeat of the paern. This can
be corrected by selecng the Point 2 Point buon.
Error messages
Motor Error with lightning bolt icon in the top‑
right corner (may occur with various types of
Motor Error messages on the screen).
This will occur with various types of motor errors.
Generally they mean that the Pro‑Stcher Lite cannot
communicate with the motors. Check that the carriage
is plugged in and that the serial cables are connected
properly into the box behind the Pro‑Stcher Lite tablet
computer. If everything is connected properly and
power is on, press the lightning bolt buon to aempt
to reestablish communicaon with the motors.
If this occurs during stching (possibly due to a large
electrostac discharge (ESD) event or power surge),
the Pro‑Stcher Lite will stop moving and wait for
the lightning bolt icon to be pressed. If the quilng
machine is sll stching at this point, press the STOP
buon on the handles. Pro‑Stcher Lite will not resume
on its own aer such a disrupon for safety reasons
and will require user intervenon to resume stching.
When communicaons are reestablished by pressing
the lightning bolt buon, it will be necessary to reset
the starng point to the posion where the stching
stopped and resume stching from that point. If the
tablet touchscreen does not respond aer such an ESD
or surge event, it may be necessary to reboot the tablet
using the power buon. A mouse may be plugged in to
an available USB port and used to save any work prior
to reboong the tablet.