132
4) A regular schedule should be formulated and batteries should be charged once every 30-45 days.
5) When the observation window does not display green, the battery should be checked and charged
or replaced.
Inspection of low-maintenance battery
As the ambient temperature around the forklift truck is high, batteries consume water; please keep an
eye on the liquid level during use; there is a filling hole on the upper cover of the battery; when the
liquid level is lower than minimum level, please add distilled water to the upper level; do not overfill
or the liquid will overflow and corrode the truck.
Check and confirm whether the liquid level
is between "UPPER LEVEL “and "LOWER
LEVEL"
1: "UPPER LEVEL"
2: "LOWER LEVEL"
If the liquid level is at or lower than “Lower
Level”, distilled water should be added.
When the electrolyte level is found to be seriously insufficient, the case should be carefully checked
for cracking, leakage or battery failure.
When the battery capacity status is normal and the electrolyte density reaches the standard, the
observation window displays green. When the battery capacity is insufficient, and the density of the
electrolyte is reduced, the observation window displays white. If the observation window displays red,
it indicates a serious shortage of electrolyte, and the case should be carefully checked for cracking,
leakage or battery failure.
See the tips on the battery label for details about battery display state.
Maintenance of low-maintenance battery
1) Ensure that the battery electrolyte is at the UPPER LEVEL.
2) Disconnect the battery negative ground strap to prevent battery discharge due to additional current
drain;
3) When batteries cannot be removed from the truck, they should be kept fully charged;
4) A regular schedule should be formulated and batteries should be charged once every 30-45 days.
5) When the battery electrolyte is below the LOWER LEVEL, please add distilled water to the UPPER
LEVEL, and put the vent plug back to the original position, and tighten it.
Caution
Avoid overfilling when adding distilled water. Overflow when refilling batteries may cause
corrosion.
2.4 Before recharging