Please turn off it when the truck is
running normally to avoid any damage to
the differential and potential rollover
when turning;
When the drive axle tires slip, the drive
axle differential lock can be used.
In other situations, please use it as
needed. (For details, please refer to the
previous rocker switch content.)
25、Regen operating instruction label
(W98/W97 engine only)
normally, it indicates that the forklift is in the
regen active status. At that time, manual
intervention is not required and normal
working status can be maintained. When the
indicator light automatically turns off, it
indicates that the particulate treatment is
completed. The driver should reduce light
running as much as possible to increase the
exhaust temperature and shorten the regen
time.
2.
Flashes, lights up: If the regen
indicator light flashes during driving and the
engine fault indicator light turns on at the
same time, please stop the forklift truck.
Contact maintenance staff or after-sales staff
to check the engine fault code. Start the
parking regen after confirming that there are
no other faults.
Parking regen conditions:
① The forklift truck is parked on a
well-ventilated flat road and the forks are
lowered.
② Make sure the forklift has enough fuel.
③ Keep the gear lever in the neutral position
(gear N).
④ Engage the hand brake.
⑤ Start the engine, release the gas pedal and
let the engine idle.
⑥ Warm up the forklift truck until the water
temperature reaches 70℃.
Start parking regen: