3 - Description
20
TurboFiller
•
•
TurboFiller Suction Valve
The valve is used simultaneously with the TurboFiller. The valve has 2
settings: Continuously open or spring loaded normally closed. Open the
valve when chemicals are to be filled into the TurboFiller and transferred
to main tank.
TurboDeflector Valve
This TurboDeflector valve activates the vortex flushing of the TurboFiller.
Lift the lever to lock it in open position for continuous liquid rotation in
the hopper.
Chemical Container Rinsing Lever
The upper lever is used for two purposes.
When the TurboFiller lid is open:
For rinsing empty containers. Place the container over the rotating
flushing nozzle in the middle of the TurboFiller to rinse the inside of the
container.
When the TurboFiller lid is closed:
Suction from TurboFiller
Start TurboDeflector