5 - Operation
50
External Filling Device (optional)
The External Filling Device is operated as follows:
1. Remove cover and connect suction hose to the suction manifold.
2. Turn pressure valve to ” Spraying, and, if the blue return valve is
mounted, turn it to Main tank.
3. Close suction valve for Main tank/RinseTanks.
4. Turn handle on External Filling Device valve towards Filling Device.
5. Engage diaphragm pump and set PTO revolutions at 540 rpm.
6. The tank is now filled with water. Keep an eye on the liquid level
indicator.
7. Turn handle on suction manifold away from Filling Device to discontinue filling process. Now disengage the pump.
8. Disconnect suction hose and replace cover.
DANGER! Prevent contamination or injury. Do not open suction valve towards Filling Device, unless the pump is
running and the filling hose is connected. If this valve is opened without the pump running, liquid will stream out of
the coupler.
±
WARNING! Do not leave the sprayer while filling the tank, and keep an eye on the level indicator in order NOT to
overfill the tank.
μ
ATTENTION! Observe local legislation regarding use of filling device. In some areas, it is prohibited to fill from open
water reservoirs (lakes, rivers etc.). It is strongly recommended only to fill from closed reservoirs (mobile water tanks
etc.) to prevent contamination.
1.
2.
3.
4.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hardi Master Plus and is the answer not in the manual?

Hardi Master Plus Specifications

General IconGeneral
BrandHardi
ModelMaster Plus
CategoryFarm Equipment
LanguageEnglish

Related product manuals