IMS-640/641 VoIP Intercom Master Station Operating Instructions MicroComm DXL
MN-DXL-IMS-640/641-1.0. Page 18
Event Queue this is a list of stations whose call requests have not been acknowledged
Acknowledged List this is a list of stations whose call requests have been acknowledged, but not canceled.
Disabled List this is a list of stations that have been disabled
Last Call List this list always contains only one entry. You use it to recall the last station you were
talking to. Every time you talk to a different station, this list is updated.
Monitor List this is a list of all intercom stations that are automatically monitored in sequence.
The following describes the Directory Lists:
Station List this is a list of all Intercom Station that can communicate with your Master Station
Station Group list this is a list of all Station Groups that can be controlled with your master station
Master List this is a list of all Master Stations that can communicate with your Master Station
Paging Zone List this is a list of all paging zones that you can make announcements to from your Master
Station.
Signal List this is a list of signals that your Master Station can activate.
Visiting Booth List this is a list of all visiting booth stations that you can communicate with, monitor, and
control their on/off status.
How Lists are Displayed
The display on your Master Station is divided into three parts:
Alarm Code and ID Number and Name for each station on the list
Note: A maximum of three stations can be displayed at one time.
The current list sizes of the Event Queue, Acknowledged List and Disabled List. These values appear on the
right-hand side of the display in the top three rows. They are always displayed.
Remember that these lists vary in size from time to time. Even if the list size is zero, a value will still appear.
A set of functions that you can perform by pressing the function keys immediately beside the display.
Let's look at this information in more detail:
Alarm Code
The alarm code indicates the type of alarm that has been received:
Alarm Code Meaning
I Intercom Station Call Request
A Audio Level Alarm Call Request
t Call Request Time-out Alarm
d Disabled Station Alarm
M Master Station or Staff Call Request
F Fault Alarm