CDi DriveCore Series Operation Manual
Installing Audio Architect & Conguring the Network
5� Proxies
This feature is used to connect to devices that cannot automatically be located by Audio Architect due to network configuration or security measures
via proxy connections.
6� Static Routes
This feature is used to set up a static route and connect directly to a device located on a different subnet than the PC.
7� Clear Container
Resets the Container/Position Venue data of the selected device. The action occurs on either "Apply Current Edits" or "Apply and Exit" so that changes
may be undone with the Undo Current Edits button.
8� Undo Current Edits
Resets any open edits in the grid to the values as currently on the network.
9� Apply Current Edits
Confirms any open edits in the grid. Devices update accordingly until connection is re-established with HiQnet NetSetter.
10� Apply and Exit
Confirms and saves any open edits in the grid. Devices update accordingly until connection is re-established with HiQnet.
NOTE: If you have made changes to NetSetter and attempt to exit the program, the confirmation window
shown in Figure 27 will appear. Clicking OK will apply the edits you have made since opening NetSetter.
Clicking Cancel will return you to the program.