Specifications
TIM40 A02590_04_E00_00 HBM: public 53
Slots for fieldbus mod
ules
Num
ber
1
Format Anybus‐CC
Protocol Profibus‐DP, CANopen
Fieldbuses
CAN Bus
Protocol - CAN 2.0B, CAL/CANopen compatible
Hardware bus link according to ISO 11898
Sampling rate Mv/s max. 1000 (PDO)
Baud rate kBaud 10 20 50 100 125 250 500 800 1000
Maximum line length m 5000 2500 1000 500 500 250 100 50 25
Profibus DP
Protocol Profibus DP Slave, according to DIN 19245‐3
Max. update rate Mv/s 1000
Baud rate MBaud max. 12
Environmental requirements
Degree of protection per
EN 60 529
IP20
Weight, approx. kg 0.65
Nominal (rated) temper
ature range
°C [°F] 0 ... +60 [+32 ... +140]
Operating temperature
range
°C [°F] -10 ... +60 [+14 ... +140]
Permissible relative
humidity, non‐condens
ing
% 10 ... 90
Mechanical stress
Vibration resistance (test per
EN60068‐2‐6)
Frequency range Hz 5 ... 65
Duration h 0.5
Acceleration (amplitude) m/s
2
25