Service and Maintenance
610 Edition September 2000
ABC
Removing Dust in the Lid
Dust may possibly need to be removed from the
glass plate in the lid to maintain constant good
quality for transparency scanning.
Proceed as follows:
1. Switch off the device.
Warning:
Pull out the power plug.
The ends of the fluorescent lamps can heat up to
100 °C when switched on.
2. Open the scanner lid.
3. Loosen both knurled screws in the cover.
4. Carefully fold the plate with the glass
pane downwards.
5. Wipe the glass pane with a lint-free cloth.
6. Screw the inner part of the lid into place.
7. Reconnect the device and switch it on.