Technical Service Guide Page 11 of 27
Web-Based Access Control Solution
ACW2-XN
Reader not powering up
Key Indicators
Reader LEDS’s should glow RED or GREEN when the reader is powered up.
Analysis
Is the reader wired correctly?
o Wire the reader correctly.
Has the maximum cable distance to the reader been exceeded?
o Ensure cable distance does not exceed maximum length.
Is the Reader defective?
o Replace reader.
Is the Wiegand Door Module defective?
o Replace Wiegand Door Module.
Is the Wiegand cable to the reader, defective?
o Replace Wiegand cable to reader (wiring is correct but is cable defective)