Page 12 of 27 Technical Service Guide
© 2017 HID Global Corporation. All rights reserved.
Web-Based Access Control Solution
ACW2-XN
Reader LED’s not working as expected
Key Indicators
Reader LED’s behaviour does not conform to what has been configured.
Analysis
Is the reader wired correctly?
o Wire all relevant reader connections, including LED control, correctly.
Have the Door Mode patterns for the door been configured correctly in the software?
o Configure the Door Mode Pattern settings in Software correctly.
Is the Reader defective?
o Replace reader.
Is the Wiegand Door Module defective?
o Replace Wiegand Door Module.
Is the Wiegand cable to the reader, defective?
o Replace Wiegand cable to reader (wiring is correct but is cable defective).