X86 Open Platform·User Manual
22
2. Select On as Trigger Mode.
3. Select LineIn 0, LineIn 1, or LineIn 2 as Trigger In Source according to actual demands.
5.3.4 Set Counter Trigger
The counter trigger provides frequency division to the external trigger signal. You can set counter
trigger as shown below.
Steps:
1. Click Trigger and IO Control > Trigger Mode.
2. Select On as Trigger Mode.
3. Select Counter 0 as Trigger In Source.
4. Set Count Number according to actual demands, and its range is from 1 to 1023.
Figure 5-4 Set Counter Trigger
5.4 Trigger Related Parameters
Under hardware trigger, you can set trigger polarity, burst frame count, trigger delay, and trigger
debouncer.
5.4.1 Set Trigger Polarity
You can set trigger activation as shown below.
Steps:
1. Click Trigger and IO Control > Trigger In Polarity.
2. Select Rising Edge, Falling Edge, High Level and Low Level as Trigger In Polarity according to
actual demands.