X86 Open Platform·User Manual
23
5.4.2 Set Burst Frame Count
Steps:
1. Click Image Setting > Acquisition Burst Frame Count.
2. Enter proper value according to actual demands, and its range is from 0 to 1023.
When Burst Frame Count= 3, 1 trigger signal outputs 3-frame image. The sequence diagram of
burst frame count is shown below.
Trigger_in1
Sensor
exposure
Exposure 1
Trigger
delay
Exposure 2
Exposure 3
Figure 5-5 Sequence Diagram of Burst Frame Count
5.4.3 Set Trigger Delay
From the device receiving signal and responding, this period is trigger delay. Its sequence diagram
is shown below.
Sensor
exposure
Exposure 1 Exposure 2 Exposure 3
Trigger_in 1
Trigger
delay
Trigger_in 2
Trigger
delay
Trigger_in 3
Trigger
delay
Figure 5-6 Signal Delay Sequence Diagram
You can set proper value in Trigger Delay, and its range is from 0 μs to 16000000 μs.
Figure 5-7 Set Trigger Delay