X86 Open Platform·User Manual
27
For specific Line Out Activation Event, please refer to following table for details.
Table 6-1 Output Event
No.
Name
Description
1
Off
It refers to disable Line Out Activation Event.
2
AcqusitionStartActive
It refers to output one I/O edge signal when starting
acquisition.
3
AcqusitionStopActive
It refers to output one I/O edge signal when stopping
acquisition.
4
FrameBurstStartActive
It refers to output one I/O edge signal when starting
triggering and acquiring images under Burst mode.
5
FrameBurstEndActive
It refers to output one I/O edge signal when stopping
triggering and acquiring images under Burst mode.
6
ExposureStartActive
It refers to output one I/O edge signal when starting
exposure.
7
CountActive
It refers to output one I/O edge signal when counter
output is enabled.
8
TimerActive
It refers to output one I/O edge signal when timer output
is enabled.
9
HardTriggerActive
It refers to output one I/O edge signal when hardware
trigger acquisition.
10
SoftTriggerOut
It refers to output one I/O edge signal when software
trigger acquisition.
11
SoftTriggerLevelOut
It refers to output one I/O level signal when software
trigger acquisition.
3. Set Line Out Delay Time(μs), Line Out Duration Time(μs), or LineOut Ahead Time(μs) for
different output events according to actual demands, as shown below.