The device adjusts the
exposure time
automatically according to
the image brightness. After
adjustment, it will switch to
Off mode.
You can set exposure mode as shown below.
Steps:
1. Click Image Setting > Exposure Auto.
2. Set Exposure Auto according to actual demands.
Figure 8-4 Set Exposure Mode
When Exposure Auto is Off, you can set exposure time by enter proper value in Exposure
Time(µs).
Figure 8-5 Set Exposure Time
When the device is under Once or Continuous exposure mode, if trigger mode is enabled, the
device will automatically switch to Off exposure mode.