Figure 4-39 Fault Check
Detect Network Camera Disconnecon
If the opon is enabled, when the linked network camera is disconnected, an alarm will be
triggered.
Panel Baery Fault Check
If the
opon is enabled, when baery is disconnected or out of charge, the device will upload
events.
Wired Network Fault Check
If the opon is enabled, when the wired network is disconnected or with other faults, the alarm
will be triggered.
Wi-Fi Fault Check
If the
opon is enabled, when the Wi-Fi is disconnected or with other faults, the alarm will be
triggered.
Cellular Network Fault Check
If the opon is enabled, when the cellular data network is disconnected or with other faults, the
alarm will be triggered.
SIM Card Fault Check
If the
opon is enabled, the alarm will be triggered for faults of the SIM card.
AC Power Down Check Time
The system checks the fault aer the congured me duraon aer AC power down.
To compliant the EN 50131-3, the check me duraon should be 10 s.