Note
The device should be installed concrete surface or other at
non-ammable surface.
If the installaon area is too close to the wall, make sure the
distance between the pedestal and the wall should be no less
than 20 mm (40 mm if with face
recognion terminals), or you
cannot open the pedestal's top panel or might cause damage
to devices.
The dimension is as follows.
Figure 2-1 Dimension
1. Draw a central line on the installaon surface of the le or
right pedestal.
2. Draw other parallel lines for installing the other pedestals.
Note
The distance between the nearest two line is L + 180 mm. L
represents the lane width.
3. Slot on the installaon surface and dig installaon holes. Put 3
expansion bolts of M12*150 for each pedestal.