Pumps Parameters
Parameter Default Min ÷ Max Description
Pump - Water
EV Switch-On Delay # sec.
0.2 0.1 ÷ 5.0 Solenoid Valve activation Delay.
Pump - Water
EV Switch-Off Delay # sec.
0.5 0.1 ÷ 5.0 Solenoid Valve deactivation Delay.
Pump - Water
Pump Sw-On Delay # sec.
0.7 0.1 ÷ 5.0 Water Pump activation delay when the traction lever is
pressed.
Pump - Water
Pump Sw-Off Delay # sec.
0.2 0.1 ÷ 5.0 Water Pump deactivation delay when the traction lever is re-
leased.
Pump - Water
Pump level #1 #%
25 0 ÷ 100 Setting of the First dispensing level.
Pump - Water
Pump level #2 #%
50 0 ÷ 100 Setting of the Second dispensing level.
Pump - Water
Pump level #3 #%
90 0 ÷ 100 Setting of the Third dispensing level.
Pump - Water
Pump Sw-On Delay # sec.
0.5 0.1 ÷ 5.0 Chemical Pump activation delay when the traction lever is
pressed.
Pump - Water
Pump Sw-Off Delay # sec.
0.5 0.1 ÷ 5.0 Chemical Pump deactivation delay when the traction lever is
released.
Pump - Water
Pulses Lenght # msec.
75 10 ÷ 2000 Pulse length of the pump.
Pump - Water
Percent. chemical %
2 0.5 ÷ 3.0 Percentage of chemical dilution.
Vacuum Parameters
Parameter Default Min ÷ Max Description
Vacuum - Vac.Motor
Maximum Current # Amp.
40 10 ÷ 40 Maximum current from the main card to the vacuum motor.
Vacuum - Vac.Motor
Nominal Current # Amp.
27 10 ÷ 40 Vacuum Motor Rated current; with T Nom manages the am-
perometric protection (alarm + stop brush motor).
Vacuum - Vac.Motor
Overload Time # sec.
30 1 ÷ 60 Vacuum Motor Rated Timer; with I Nom manages the amper-
ometric protection (alarm + stop brush motor).
Vacuum - Vac.Motor
Switch-On Delay # sec.
0.2 0.1 ÷ 5.0 Brush Motor Switch on Delay when the traction lever is
pressed.
Vacuum - Vac.Motor
Switch-Off1 Delay # sec.
10 1 ÷ 300 (Off function) Brush Motor Switch off Delay when the traction
lever is released.
Vacuum - Vac.Motor
Reset Delay # sec.
300 1 ÷ 300 Reset Timing from amperometric protection.
Vacuum - Vac.Motor
Vacuum Noise Level 1 # V
17 12 ÷ 24 Motor working Voltage, Level 1.
Vacuum - Vac.Motor
Vacuum Noise Level 2 # V
20 12 ÷ 24 Motor working Voltage, Level 2.
Vacuum - Vac.Motor
Vacuum Noise Level 3 # V
24 12 ÷ 24 Motor working Voltage, Level 3.