Parameter Default Min ÷ Max Description
Traction - Motor Sets
Maximum Current # Amp.
45 10 ÷ 45 Maximum current from the main card to the traction motor.
Traction - Motor Sets
Nominal Current # Amp.
10 5 ÷ 15 Traction motor Rated current; with T Nom manages the am-
perometric protection (alarm + stop brush motor).
Traction - Motor Sets
Overload Time # sec.
10 1 ÷ 30 Traction motor Rated Timer; with I Nom manages the amper-
ometric protection (alarm + stop brush motor).
Traction - E-Brake
Switch-Off Delay # sec.
1.5 0.0 ÷ 10.0 Electrobrake release delay.
Traction - E-Brake
E-Brake Check # sec.
Yes No ÷ Yes Electrobrake operation Check.