5.2.2 Checking the nail stand-off
1. Use the test gauge to check the nail stand-off.
Result 1 / 3
Nail stand-off is within the required range.
The tool power setting is incorrect. The test is
complete.
Result 2 / 3
Nail stand-off is too high.
Increase the power setting by turning the power
regulation wheel to the next higher setting.
If the power regulation wheel is already set to the
highest value, use a more powerful cartridge type
if available.
Result 3 / 3
Nail stand-off is too low.
Reduce the power setting by turning the power
regulation wheel to the next lower setting.
If the power regulation wheel is already set to the
lowest value, use a less powerful cartridge type
if available.
2. Drive another fastener.
3. Repeat the previously described steps until the correct nail stand-off is achieved.
5.2.3 Adjusting the power setting
@
Power regulation wheel
;
Power setting indicator
Turn the power regulation wheel to set the desired
nail driving power.
The current power setting is indicated.
Printed: 30.04.2019 | Doc-Nr: PUB / 5491711 / 000 / 00

Other manuals for Hilti DX 9–ENP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hilti DX 9–ENP and is the answer not in the manual?

Hilti DX 9–ENP Specifications

General IconGeneral
BrandHilti
ModelDX 9–ENP
CategoryPower Tool
LanguageEnglish

Related product manuals