EasyManuals Logo

Hilti DX 9–ENP Operating Instructions

Hilti DX 9–ENP
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
English 15
5.2.4 Removing cartridges from the tool
1. Press the cartridge strips forward, as far as possible, in the direction of advance.
2. Pull the cartridge strips out of the tool at the cartridge strip exit aperture.
5.2.5 Removing fasteners from the tool
The fasteners can normally remain in the tool. It is not necessary to remove them, for example, when
you are finished working with the tool.
1. Check that the cartridges have already been removed from the tool. page 15
2. Stand the tool on its grip.
3. Press the red latch at the mouth of the magazine and allow the nail strips to slide back out of the
magazine.
4. While pressing the catch, pull the nail strip out of the tool.
If the nail strip does not project from the base plate, work through the sequence of steps below.
5. Stand the tool upright in the working position.
6. Press the stop.
7. Cycle the tool until the nail strip projects from the tool.
6 Care and maintenance
6.1 Check the piston and piston stopper and replace the parts if necessary
If a fastener is driven incorrectly, the piston may become jammed in the piston stopper. If the piston
and piston stopper become fully seized in this way, these parts have reached the end of their life. The
tool cannot be cycled when in this state.
The condition of the piston and piston stopper must be checked at regular intervals and at least daily.
Printed: 30.04.2019 | Doc-Nr: PUB / 5491711 / 000 / 00

Other manuals for Hilti DX 9–ENP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hilti DX 9–ENP and is the answer not in the manual?

Hilti DX 9–ENP Specifications

General IconGeneral
BrandHilti
ModelDX 9–ENP
CategoryPower Tool
LanguageEnglish

Related product manuals