5.3 Measurement specifications
154
When using a current sensor with a rating of 5,000 A (with the CT ratio set to 100)
CT9667 (5,000 A): TYPE1
When using the 9660 (TYPE1) (rated current: 100 A; with the CT ratio set to 10)
Measurement accuracy External current sensor input instrument measurement accuracy only
When input is less than 50% of the range
When input is 50% or more of the range but less than 100%
Voltage range
Range noted
on panel
Current
range
Wiring 15.000 V 30.000 V 60.000 V 150.00 V 300.00 V 600.00 V 1.0000 kV
10 A 1.0000 kA
1P2W 15.000 k 30.000 k 60.000 k 150.00 k 300.00 k 600.00 k 1.0000 M
Other than
1P2W or 3P4W
30.000 k 60.000 k 120.00 k 300.00 k 600.00 k 1.2000 M 2.0000 M
3P4W 45.000 k 90.000 k 180.00 k 450.00 k 900.00 k 1.8000 M 3.0000 M
20 A 2.0000 kA
1P2W 30.000 k 60.000 k 120.00 k 300.00 k 600.00 k 1.2000 M 2.0000 M
Other than
1P2W or 3P4W
60.000 k 120.00 k 240.00 k 600.00 k 1.2000 M 2.4000 M 4.0000 M
3P4W 90.000 k 180.00 k 360.00 k 900.00 k 1.8000 M 3.6000 M 6.0000 M
50 A 5.0000 kA
1P2W 75.000 k 150.00 k 300.00 k 750.00 k 1.5000 M 3.0000 M 5.0000 M
Other than
1P2W or 3P4W
150.00 k 300.00 k 600.00 k 1.5000 M 3.0000 M 6.0000 M 10.000 M
3P4W 225.00 k 450.00 k 900.00 k 2.2500 M 4.5000 M 9.0000 M 15.000 M
Units: W (active power), VA (apparent power), var (reactive power)
Voltage range
Range noted
on panel
Current
range
Wiring 15.000 V 30.000 V 60.000 V 150.00 V 300.00 V 600.00 V 1.0000 kV
10 A 100.00A
1P2W 1.5000 k 3.0000 k 6.0000 k 15.000 k 30.000 k 60.000 k 100.00 k
Other than
1P2W or 3P4W
3.0000 k 6.0000 k 12.000 k 30.000 k 60.000 k 120.00 k 200.00 k
3P4W 4.5000 k 9.0000 k 18.000 k 45.000 k 90.000 k 180.00 k 300.00 k
Units: W (active power), VA (apparent power), var (reactive power)
Frequency(f) Voltage Current, Active power
DC ±0.1%rdg.±0.1%f.s. ±0.2%rdg.±0.6%f.s.
0.1Hz f < 16Hz ±0.1%rdg.±0.2%f.s. ±0.2%rdg.±0.2%f.s.
16Hz f < 45Hz ±0.1%rdg.±0.1%f.s. ±0.2%rdg.±0.2%f.s.
45Hz f 66Hz ±0.1%rdg.±0.05%f.s. ±0.2%rdg.±0.1%f.s.
66Hz < f 500Hz ±0.1%rdg.±0.1%f.s. ±0.2%rdg.±0.2%f.s.
500Hz < f 1kHz ±0.1%rdg.±0.2%f.s. ±0.2%rdg.±0.3%f.s.
1kHz < f 10kHz ±0.1%rdg.±0.2%f.s. ±5.0%f.s.
10kHz < f 50kHz ±0.5%rdg.±0.3%f.s. -
50kHz < f 100kHz ±2.1%rdg.±0.3%f.s. -
Frequency(f) Voltage Current, Active power
DC
±0.1%rdg.±0.1%f.s. ±0.2%rdg.±0.6%f.s.
0.1Hz f < 16Hz
±0.3%rdg. ±0.4%rdg.
16Hz f < 45Hz
±0.2%rdg. ±0.4%rdg.
45Hz f 66Hz
±0.15%rdg. ±0.3%rdg.
66Hz < f 500Hz
±0.2%rdg. ±0.4%rdg.
500Hz < f 1kHz
±0.3%rdg. ±0.5%rdg.
1kHz < f 10kHz
±0.3%rdg. ±5.0%rdg.
10kHz < f 50kHz
±0.8%rdg. -
50kHz < f 100kHz
±2.4%rdg. -