Installation MSP30/32/40/42 and MSM20/22/24/40/42/46/50
Release
12
06/2018
7
Qualified personnel have the following characteristics:
Qualified personnel are properly trained. Training as well as practical
knowledge and experience make up their qualifications. This is the
prerequisite for grounding and labeling circuits, devices, and systems
in accordance with current standards in safety technology.
Qualified personnel are aware of the dangers that exist in their work.
Qualified personnel are familiar with appropriate measures against
these hazards in order to reduce the risk for themselves and others.
Qualified personnel receive training on a regular basis.
Installation site requirements
Verify that there is at least 4 in (10 cm) of space above and below the
device.
Verify that there is at least 0.8 in (2 cm) of space on the right and left
sides of the device.
Install the device at ambient temperatures greater than 113 °F (45 °C)
in “restricted access locations” based on EN 60950-1 exclusively.
Device casing
Only technicians authorized by the manufacturer are permitted to open
the casing.
Never insert pointed objects (narrow screwdrivers, wires, etc.) into the
device or into the connection terminals for electric conductors. Do not
touch the connection terminals.
Make sure there is at least 3.94 in (10 cm) of space in front of the
ventilation slits of the casing.
Keep the ventilation slits free to ensure good air circulation.
If you are operating the device in a living area or office environment,
only operate it in switch cabinets with fire protection characteristics in
accordance with EN 60950-1.
The surfaces of the device housing may become hot. Avoid touching
the device while it is operating.
Note: The basic device is an inseparable unit. The basic device may be
damaged by detachment of the display and connection part.
Grounding the device
Grounding the device is by means of a separate ground connection on the
device.
Ground the device before connecting any other cables.
Disconnect the grounding only after disconnecting all other cables.
The overall shield of a connected shielded twisted pair cable is connected
to the grounding connector on the front panel as a conductor.