EMC and immunity
EMC compliance – IEC/EN 61000-6-2:2005 EMI TYPE tests, test acc. to:
IEC/EN 61000-4-2 Electrostatic discharge
Contact discharge
Air discharge
6 kV
8 kV
IEC/EN 61000-4-3 Electromagnetic field
80 - 3,000 MHz 10 V/m
IEC/EN 61000-4-4 Fast transients (burst)
Power line
Data line
2 kV
4 kV
IEC/EN 61000-4-5 Voltage surges
Power line, line / line
Power line, line / earth
Data line
1 kV
2 kV
2 kV
IEC/EN 61000-4-6 Line-conducted interference voltages
150 kHz - 80 MHz 10 V
EN 61000-4-9 Impulse-shaped magnetic fields 300 A/m
EMC emitted interference
EN 55022 Class A Yes
FCC 47 CFR Part 15 Class A Yes
German Lloyd Classification + Construction Guidelines VI-7-3 Part 1 Ed.2001 Yes
Stability
Vibration IEC 60068-2-6 Test FC test level according to IEC 61131-2 Yes
Germanischer Lloyd Guidelines for the Performance of Type
Tests Part 1
Yes
Shock IEC 60068-2-27 Test Ea test level according to IEC 61131-2 Yes