PowerMICE
Release
 
01
 
04/2014
49
 Power consumption/power output, temperature range and 
order numbers
Note: For the extended temperature range, use suitable modules and 
transceivers. You will identify these components by the “EEC” name 
extension or the open variant product code “E” (postion 15).
TP port
Length of a twisted pair segment max. 100 m/328 ft (for cat5e cable)
Table 15: TP port 10BASE-T / 100BASE-TX / 1000BASE-T
AU port
Length of an AUI cable max. 50 m
Table 16: AUI port
Basic module Power 
consumpti
on
Power output Operating 
temperature 
(ambient air 
temperature)
Order 
number
MS4128-L2P 16.0 W 54.7 Btu (IT)/h 0 °C to +60 °C 943 009-102
MS4128-L3E 16.0 W 54.7 Btu (IT)/h 0 °C to +60 °C 943 009-202
MS4128-L3P 16.0 W 54.7 Btu (IT)/h 0 °C to +60 °C 943 009-302
MS4128-L2P ATEX 16.0 W 54.7 Btu (IT)/h 0 °C to +60 °C 943 009-101
MS4128-L3E ATEX 16.0 W 54.7 Btu (IT)/h 0 °C to +60 °C 943 009-201
MS4128-L3P ATEX 16.0 W 54.7 Btu (IT)/h 0 °C to +60 °C 943 009-301
MS4128-L2P EEC 16.0 W 54.7 Btu (IT)/h -30 °C to +60 °C 943 009-103
MS4128-L3E EEC 16.0 W 54.7 Btu (IT)/h -30 °C to +60 °C 943 009-203
MS4128-L3P EEC 16.0 W 54.7 Btu (IT)/h -30 °C to +60 °C 943 009-303
Table 17: Basic module: power, temperature, order numbers