11
5.1.3.4 Domestic Hot Water Running
Step 1
Power on, the default state of wire remote
controller will appear, and previously running
function may appear on the LCD screen. According
to the actual mounting (refer to 5.1.7 In-situ
Settings “d3”), press function key to show
domestic hot water ; continuously press function
key to shift the icon between floor heating and
domestic hot water until the domestic hot water is
selected.
Heating
Domestic Hot
Water
Step 2
To increase water tank temperature, press “ġ” of
the temperature setting key ; if it is reduced,
press “Ģ . For domestic hot water, the highest
water outlet set temperature is 75°C, and the
lowest set temperature is 35°C.
Water Tank
Temperature Code
Water Tank Set Temperature
Actual Water
Tank Temperatur
Begin Running
Step 3
, the LED lamp on, and the
machine begins running.
5.1.3.5 Powerful Water Storage Running
Step 1
Before powerful water storage, go to “5.1.7 In-situ
Settings”, set the target temperature for powerful
water storage of water tank (“F6”), and also set the
“Electric Heating of Water Tank” (“d8”) as active.
Step 2
At the standby state, press the hot water key for
3 seconds, and go to powerful water storage.
Domestic Hot Water
Electric Heater of Water Tank
Step 3
After going to powerful water storage, the domestic
hot water and electric heater
is running.
Step 4
After powerful water storage starts, quit from the
powerful water storage under the following 3
conditions
(1) At powerful water storage mode, press the hot
water key for 3 seconds.
(2) When the water tank temperature reaches the
set water temperature for powerful water
storage (5.1.7 In-situ Settings “F6”).
, the machine stops
running.
5.1.3.6 Heat Recovery
Step 1
At the standby state, set “Heat Recovery” function
as active (5.1.7 In-situ Settings “E8=1”) and the
domestic water tank mode active (5.1.7 In-situ
Settings “d3=1”). At the indoor air conditioner
cooling mode, it automatically turns to heat recovery
function.
Domestic Hot
Water
Press key
ON/OFF
at 1 Hz.
This means powerful water storage
(3) Press key
ON/OFF
Heating
flashes at 1 Hz
flashes at 1 Hz

Table of Contents