Table 1-20 Example for CB 520A A1 when Onboard LAN Card is not
installed (Emulex 10Gb 4ports)
Physical NIC
Physical Port
No. 
1
Logical Port
No. 
2
Detection No.
of LAN
controller
Network
segment
Mezzanine Card
1
(Emulex 10Gb
4ports)
0 2 2 2av
1 3 2bv
2 0 1 1av
3 1 1bv
Notes:
1. The physical port number which exists on the system.
2. The logical port number which displays on the LPAR manager screen.
Table 1-21 Example for CB 540A A1/B1, CB 520X B1/B2/B3 when Onboard
LAN Card is not installed (Emulex 10Gb 4ports)
Physical NIC
Physical Port No.
1
Logical
Port No. 
2
Detection No. of
LAN controller
Network
segment
Mezzanine Card 1
(Emulex 10Gb
4ports)
0 0 1 1av
1 1 1bv
2 2 2 2av
3 3 2bv
Mezzanine Card 3
(Emulex 10Gb
4ports)
3
0 0 3 3av
1 1 3bv
2 2 4 4av
3 3 4bv
Notes:
1. The physical port number which exists on the system.
2. The logical port number which displays on the LPAR manager screen.
3. NIC cannot be installed on Mezzanine Card 3 for CB 520X B1.
1-30
LPAR manager Functions
Hitachi Compute Blade 500 Series Logical partitioning manager User's Guide