Terminalblocks1
Lead-inPort
Communicationconnector(OptionalonRX2-B)
Ethernetcommunicationconnector
(Option:Dependingonmodels)
Name
Forseparatecode
Forexternalcommunications
Forprinttargetdetector/
forencoder
Forreciprocativeprinting,
Print-in-progress,
Print.complete,printstop,
online,remotesignal
ForReady,Fault,Warning
φ4.5〜10(M16)
φ3.5〜10
φ3.5〜7(M12)
φ4.5〜10(M16)
φ4.5〜10(M16)
Cableoutside
diameterrange
[Lead-inport]
19(d)
38(W)×17(H)
15(d)
19(d)
19(d)
d
W
H
Size/Dimension
4.2 Input/output (I/O) signal connection
4.2.1 Wiring the I/O line
Open the top cover and run the I/O line wiring from the lead-in port on the side and connect it to external
connection terminal boards 1 and 2 and the external communications connector inside the IJ printer.
When performing wiring work, always turn off the power.
During normal use, leave the top cover closed.
CAUTION
Use cables with an outside diameter within the range specified above. Firmly tighten
the lead-in port lock nut.
In addition, do not bundle weak electric system and strong electric system cables
together inside and outside the IJ printer so that the weak electric system signals
(signals to terminal board 1 and external communication connector) are not affected by
strong electric system signals (power source).
Especially, absolutely never bundle together the print target detector and print stop
signals and the power source and Ready to print signal cable and do not wire them
inside the same duct.
CAUTION