5-34 ●Transmission Sequences
5.3.10 Remote Operation Transmission
5.3.10-1 Text
ESC2 Header 72H Type
Type
30H:Operation start
31H:Operation stop
32H:Deflection voltage control (ON)
33H:Deflection voltage control (OFF)
34H:Fault clear
ESC Header 71H Type
[Existing machine message] Existing machine message can also be used.
5.3.10-2 Types of control
Types of control for operation
No. Type Content Function enabled status
1 Operation start
Starts to jet ink, and shifts from stop status to ready
status.
(Same process as with <Startup> button)
Stop status
2 Operation stop
Stops ink jet, and shifts to stop status (Same process as
with <Shutdown> button)
When ink is being jetted
(standby, ready status, etc.)
3
Deflection
voltage control
(ON)
Turns deflection voltage on
(Same process as with <Ready> button in Manual
control menu window)
Standby status
4
Deflection
voltage control
(OFF)
Turns deflection voltage off
(Same process as with <Standby> button in Manual
control menu window)
Ready status
5 Fault clear
Closes the window for any fault that has occurred.
However, the window will remain if the cause of fault
is not resolved.
When fault has occurred
● Specify only one category of control at a time.
● Even if executing function is not possible, ACK will be answered, but no function will be executed.