5-34 Transmission Sequences
5.3.10 Remote Operation Transmission
5.3.10-1 Text
ESC2 Header 72H Type
Type
30H:Operation start
31H:Operation stop
32H:Deflection voltage control (ON)
33H:Deflection voltage control (OFF)
34H:Fault clear
ESC Header 71H Type
[Existing machine message] Existing machine message can also be used.
5.3.10-2 Types of control
Types of control for operation
No. Type Content Function enabled status
1 Operation start
Starts to jet ink, and shifts from stop status to ready
status.
(Same process as with <Startup> button)
Stop status
2 Operation stop
Stops ink jet, and shifts to stop status (Same process as
with <Shutdown> button)
When ink is being jetted
(standby, ready status, etc.)
3
Deflection
voltage control
(ON)
Turns deflection voltage on
(Same process as with <Ready> button in Manual
control menu window)
Standby status
4
Deflection
voltage control
(OFF)
Turns deflection voltage off
(Same process as with <Standby> button in Manual
control menu window)
Ready status
5 Fault clear
Closes the window for any fault that has occurred.
However, the window will remain if the cause of fault
is not resolved.
When fault has occurred
Specify only one category of control at a time.
Even if executing function is not possible, ACK will be answered, but no function will be executed.