Communication Buffer 5-67
5.9.4 Errors
(1) Errors during external communications
Errors during print content transmission and print data call-up
No. Condition Type of error
1
Not all received print contents could be held in buffer because
its capacity was exceeded
NAK is returned.
However, this will not cause any
external communication error.
2 Number of print items of received contents is more than 9. External communication error 030
3
Calendar or count character was included in print data call-up
transmission
External communication error 027
Error when buffer is cleared
No. Condition Type of error
1 Text was transmitted together with another text External communication error 002
(2) Errors during printing
Errors during printing
No. Condition Type of error
1
The number of received contents in buffer was less than "Data
number at Fault".
Fault "Communication Buffer
Fault"
2
Print start signal was received during print data switching
immediately after ACK was returned to "restart printing"
Fault
"Invalid Data Change Timing"
When "communication buffer fault" occurs, the window will be cleared, followed by standby
status.
(3) Error when status is changed
Error when status is changed
No. Condition Type of error
1
Calendar characters or count characters were included to
existing print contents when restored to online.
Confirmation message
"Communication buffer error"

Table of Contents

Related product manuals