Example: Automatic temperature Reset for 25 °C in air
conditioning:
Figu
re
Description
A
Temperature setting changed from 25 °C to 20 °C using
the remote control.
B The cold operation at 20°C is temporarily enabled
C
If the operation is not defined within a specific period, the
temperature configuration returns to 25 °C automatically.
F4 – Automatic release time
This function is used to set the automatic release time with the temperature setting.
Setting
Condition setting
00 30 minutes (factory setting)
01 15 minutes
02 60 minutes
03 90 minutes
F5 – Automatic cooling temperature release
This function is used to set automatic temperature release for the FAN/COOL/DRY functions.
Setting
Condition setting
19 19 °C
20 20 °C
21-24 (21-24) °C
25 25 °C (factory setting)
26-28 (26-28) °C
29 29 °C
30 30 °C