Chapter 4 Explanation of Functions
4-46
4.2.39 Intelligent input terminal setting
You can assign the functions described below to intelligent input terminals
[1] to [8]. To assign the desired functions to the terminals, specify the
desired data listed in the table below for terminal settings "C001" to
"C008". For example, "C001" corresponds to intelligent input terminal [1].
You can select the a-contact or b-contact input for individual intelligent input terminals.
You can assign one function only to an intelligent input terminal. If you have attempted to assign a function to two or
more intelligent input terminals, the function is assigned to only the terminal to which you have last attempted
assignment. Function data "NO" (no assign) is assigned to other terminals, and those terminals are ineffective in terms
of functions.
After assigning the desired functions to intelligent input terminals [1] to [8], confirm that the assigned functions have
been stored on the inverter.
CF1: Multispeed 1 setting (binary operation)
Multispeed operation function
CF2: Multispeed 2 setting (binary operation)
CF3: Multispeed 3 setting (binary operation)
CF4: Multispeed 4 setting (binary operation)
Jogging operation function
DC braking (external DC braking) function
2nd/3rd motor control function
2CH: 2-stage acceleration/deceleration
2-stage acceleration/deceleration function
USP: Unattended start protection
Unattended start protection function
CS: Commercial power source enable
Commercial power supply switching function
SFT: Software lock (control circuit terminal block)
AT: Analog input voltage/current select
External analog input setting function
2nd/3rd motor control function
STA: Starting by 3-wire input
STP: Stopping by 3-wire input
F/R: Forward/reverse switching by 3-wire input
CAS: Control gain setting
Control gain switching function
UP: Remote control UP function
Remote control (UP/DWN) function
DWN: Remote control DOWN function
DWN: Remote control data clearing
Forcible-operation function
SF1: Multispeed 1 setting (bit operation)
Multispeed operation function
SF2: Multispeed 2 setting (bit operation)
SF3: Multispeed 3 setting (bit operation)
SF4: Multispeed 4 setting (bit operation)
SF5: Multispeed 5 setting (bit operation)
SF6: Multispeed 6 setting (bit operation)
SF7: Multispeed 7 setting (bit operation)
OLR: Overload restriction selection
Overload restriction function
Torque limitation function
TRQ1: Torque limit selection bit 1
TRQ2: Torque limit selection bit 2
BOK: Braking confirmation
LAD cancellation function
PCLR: Clearance of position deviation
V2 control mode selection function
STAT: Pulse train position command input enable
ADD: Trigger for frequency addition (A145)
Frequency addition function
C001 to C008: Terminal [1] to [8] functions