Chapter 8 List of Data Settings
8-3
8.4 Extended Function Mode
Monitored data or setting
Change during
RUN operation
00 (keypad potentiometer) (*1), 01 (control circuit terminal block),
02 (digital operator), 03 (RS485), 04 (option 1), 05 (option 2),
06 (pulse-string input), 07 (easy sequence),
10 (operation function result)
Run command source setting
01 (control circuit terminal block), 02 (digital operator), 03 (RS485),
04 (option 1), 05 (option 2)
30. to "Maximum frequency " (Hz)
Base frequency setting, 2nd motor
30. to "Maximum frequency, 2nd motor" (Hz)
Base frequency setting, 3rd motor
30. to "Maximum frequency, 3rd motor" (Hz)
Maximum frequency setting
"Base frequency setting " to 400. (Hz)
Maximum frequency setting, 2nd motor
"Base frequency setting, 2nd motor " to 400. (Hz)
Maximum frequency setting, 3rd motor
"Base frequency setting, 3rd motor " to 400. (Hz)
00 (switching between O and OI terminals),
01 (switching between O and O2 terminals),
02 (switching between O terminal and keypad potentiometer) (*1),
03 (switching between OI terminal and keypad potentiometer) (*1),
04 (switching between O2 and keypad potentiometer) (*1)
00 (single),
01 (auxiliary frequency input via O and OI terminals) (nonreversible),
02 (auxiliary frequency input via O and OI terminals) (reversible),
03 disabling O2 terminal)
[O]-[L] input active range start frequency
0.00 to 99.99, 100.0 to 400.0 (Hz)
[O]-[L] input active range end frequency
0.00 to 99.99, 100.0 to 400.0 (Hz)
(In case of setting 0.00, internal setting is "Maximum frequency ")
[O]-[L] input active range start voltage
0. to "[O]-[L] input active range end voltage" (%)
[O]-[L] input active range end voltage
"[O]-[L] input active range start voltage" to 100. (%)
[O]-[L] input active range start frequency
selection
00 (external start frequency), 01 (0 Hz)
External frequency filter time const.
1. to 30. or 31. (500 ms filter ±0.1 Hz with hysteresis)
Easy sequence function selection
00 (disabling), 01 (enabling)
Multispeed operation and jogging
Multispeed operation selection
00 (binary: 16 speeds selectable with 4 terminals),
01 (bit: 8 speeds selectable with 7 terminals)
Multispeed frequency setting
0.0 or “start frequency” to “maximum frequency” (Hz)
Multispeed frequency setting, 2nd motor
0.0 or “start frequency” to “maximum frequency, 2nd motor” (Hz)
Multispeed frequency setting, 3rd motor
0.0 or “start frequency” to “maximum frequency, 3rd motor” (Hz)
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
0.0 or “start frequency” to “1st maximum frequency” (Hz) (n=1 to 3)
"Start frequency" to 9.99 (Hz)
00 (free-running after jogging stops [disabled during operation]),
01 (deceleration and stop after jogging stops [disabled during operation]),
02 (DC braking after jogging stops [disabled during operation]),
03 (free-running after jogging stops [enabled during operation]),
04 (deceleration and stop after jogging stops [enabled during operation]),
05 (DC braking after jogging stops [enabled during operation])
*1 This setting is valid only when the OPE-SR is connected.