Chapter 4 Explanation of Functions
4-78
(4) Basic display mode
The monitor displays basic parameters. (The monitor display is the factory setting.)
The following table lists the parameters that can be displayed in basic display mode:
Acceleration (1) time setting
Deceleration (1) time setting
Run command source setting
Maximum frequency setting
Multispeed frequency setting
V/F characteristic curve selection, 1st motor
Selection of restart mode
Allowable under-voltage power failure time
Selection of retry after trip
Retry wait time after trip
Function code display restriction
Carrier frequency setting
Initialization mode (parameters or trip history)
Overvoltage suppression enable
Overvoltage suppression level
4.2.85 Initial-screen selection (selection of the initial screen to be displayed after power-on)
The initial-screen selection function allows you to specify the screen that is
displayed on the digital operator immediately after the inverter power is turned
on. The table below lists the screens (items) selectable. (The factory setting is
"01" [d001].)
To adjust the screen selection setting of your SJ700 series inverter to an SJ300 series inverter, select "00" (the screen
displayed when the STOP/RESET key was last pressed).
Screen displayed when the STR key was pressed last
(equivalent to the setting on SJ300)
d001 (output frequency monitoring)
d002 (output current monitoring)
d003 (rotation direction minitoring)
d007 (Scaled output frequency monitoring)
F001 (output frequency setting)
Note: When "00" (the screen displayed when the STR key was last pressed) has been selected, the monitor displays
code "*---" (entry to a group of functions) if the functional item displayed last is not "d***" or "F***".
(Example) If the inverter power is turned off immediately after the setting of "A020" has been changed, the
monitor will display "A---" as the initial screen after the next power-on.
b038: Initial-screen selection