Chapter 4 Explanation of Functions
4-121
(v) 04 command: This command reads the status of the inverter.
- Transmission frame
Frame format
Control code (Start of TeXt)
Station number of control-target
inverter
Command to be transmitted
XOR of the items from "Station No." to "Data." See
Item (3) of this section.
Control code (Carriage Return)
- Response frame
Frame format
Control code (Start of TeXt)
Station number of control-target
inverter
XOR of the items from "Station No." to "Data." See
Item (3) of this section.
Control code (Carriage Return)
Note 10: The data indicating the status of the inverter consists of the following three status elements (A, B, and C):
Data
Inverter status A Inverter status B Inverter status C
Free-run stop (FRS) in progress
DC braking (DB) in progress
Switching forward operation
Switching reverse operation
Starting forward operation
Starting reverse operation