Monitoring and setting items Data resolution
Reduced voltage start selection
0 (minimum reduced voltage start time) to 255
(maximum reduced voltage start time)
Function code display restriction
0 (full display), 1 (function-specific display), 2 (user
setting), 3 (data comparison display), 4 (basicdisplay)
0 (screen displayed when the STR key was pressed last),
1 (d001), 2 (d002), 3 (d003), 4 (d007), 5 (F001)
Automatic user-parameter setting
function enable
0 (disabling), 1 (enabling)
00 (quadrant-specific setting), 01 (switching by
terminal), 02 (analog input), 03 (option 1),
04 (option 2)
Torque limit (1) (forward-driving in
4-quadrant mode)
Torque limit (2)
(reverse-regenerating in 4-quadrant
mode)
Torque limit (3) (reverse-driving in
4-quadrant mode)
Torque limit (4)
(forward-regenerating in
4-quadrant mode)
Torque limit LADSTOP enable
0 (disabling), 1 (enabling)
Reverse Run protection enable
0 (disabling), 1 (enabling)
Controller deceleration and stop on
power loss
0 (disabling), 1 (enabling), 2, (nonstop operation at
momentary power failure (no restoration))
3, (nonstop operation at momentary power failure
(restoration to be done))
DC bus voltage trigger level during
power loss
Over-voltage threshold during
power loss
Deceleration time setting during
power loss (target voltage level)
Initial output frequency decrease
during power loss
Proportional gain setting for
nonstop operation at momentary
power failure
Integral time setting for nonstop
operation at momentary power
failure
Maximum-limit level of window
comparators O
0. to 100. (lower limit : b061 + b062 *2) (%)
Minimum-limit level of window
comparators O
0. to 100. (lower limit : b060 - b062*2) (%)
Hysteresis width of window
comparators O
0. to 10. (lower limit : b061 - b062 / 2) (%)
Maximum-limit level of window
comparators OI
0. to 100. (lower limit : b064 + b066 *2) (%)
Minimum-limit level of window
comparators OI
0. to 100. (lower limit : b063 - b066 *2) (%)
Hysteresis width of window
comparators OI
0. to 10. (lower limit : b063 - b064 / 2) (%)
Maximum-limit level of window
comparators OI
-100. to 100. (lower limit : b067 + b068 *2) (%)
Minimum-limit level of window
comparators O/OI/O2
-100. to 100. (lower limit : b066 - b068 * 2) (%)
Hysteresis width of window
comparators O/OI/O2
0. to 10. (lower limit : b066 - b067 / 2) (%)
Operation level at O disconnection
0. to 100. (%) or "no" (ignore)
Operation level at OI disconnection
0. to 100. (%) or "no" (ignore)
Operation level at O2 disconnection
-100. to 100. (%) or "no" (ignore)
Cumulative input power data
clearance
Cumulative input power display
gain setting