Chapter 8 List of Data Settings
8-15
Monitored data or setting
Change during
RUN operation
Pulse-string frequency scale
Time constant of pulse-string frequency filter
Pulse-string frequency bias
Pulse-string frequency limit
Absolute position control
Multistage position setting 0
Position setting range reverse side to forward side
(upper 4 digits including “-“)
Multistage position setting 1
Position setting range reverse side to forward side
(upper 4 digits including “-“)
Multistage position setting 2
Position setting range reverse side to forward side
(upper 4 digits including “-“)
Multistage position setting 3
Position setting range reverse side to forward side
(upper 4 digits including “-“)
Multistage position setting 4
Position setting range reverse side to forward side
(upper 4 digits including “-“)
Multistage position setting 5
Position setting range reverse side to forward side
(upper 4 digits including “-“)
Multistage position setting 6
Position setting range reverse side to forward side
(upper 4 digits including “-“)
Multistage position setting 7
Position setting range reverse side to forward side
(upper 4 digits including “-“)
Zero-return mode selection
00(Low) / 01 (Hi1) / 00 (Hi2)
Zero-return direction selection
Low-speed zero-return frequency
High-speed zero-return frequency
0.00 to 99.99 / 100.0 to Maximum frequency setting,
1
st
motor (Hz)
Position range specification (forward)
0 to 268435455 (when P012 = 02)
0 to 1073741823 (when P012 = 03) (upper 4 digits)
Position range specification (reverse)
-268435455 to 0 (when P012 = 02)
-1073741823 to 0 (when P012 = 03) (upper 4 digits)
00 (X00) / 01 (X01) / 02 (X02) / 03 (X03) /
04 (X04) / 05 (X05) / 06 (X06) / 07 (X07) /
Easy sequence user parameter U (00)
0. to 9999., 1000 to 6553 (10000 to 65535)
Easy sequence user parameter U (01)
0. to 9999., 1000 to 6553 (10000 to 65535)
Easy sequence user parameter U (02)
0. to 9999., 1000 to 6553 (10000 to 65535)
Easy sequence user parameter U (03)
0. to 9999., 1000 to 6553 (10000 to 65535)
Easy sequence user parameter U (04)
0. to 9999., 1000 to 6553 (10000 to 65535)
Easy sequence user parameter U (05)
0. to 9999., 1000 to 6553 (10000 to 65535)
Easy sequence user parameter U (06)
0. to 9999., 1000 to 6553 (10000 to 65535)
Easy sequence user parameter U (07)
0. to 9999., 1000 to 6553 (10000 to 65535)
Easy sequence user parameter U (08)
0. to 9999., 1000 to 6553 (10000 to 65535)
Easy sequence user parameter U (09)
0. to 9999., 1000 to 6553 (10000 to 65535)
Easy sequence user parameter U (10)
0. to 9999., 1000 to 6553 (10000 to 65535)
(Note) < >indicate the setting range of 75 to 150kW