Adding trap notification for SNMP v3
This topic describes the procedure to add IP addresses and users to trap notication for
SNMP v3.
Before you begin
You must have the Storage Administrator (Initial Conguration) role to perform this task.
For more information, see the System Administrator Guide.
Procedure
1. Display the Device Manager - Storage Navigator main window.
2. From the Settings menu, select Environmental Setting > Edit Alert Settings.
3. Select the SNMP tab.
4. Under SNMP Agent, click Enable.
5. Under SNMP Version, select v3.
6. Under Registered Sending Trap Settings, click Add.
7. In the Add Sending Trap Setting window, under Send Trap To, select IPv4 or IPv6,
and enter an IP address.
Note: Any IP address that has all values set to zero (0) cannot be
specied for IPv4 and IPv6. The IPv6 address is specied by entering
eight hexadecimal numbers that are separated by colons (:) using a
maximum of 4 digits from zero (0) to FFFF inclusive. The default form of
the IPv6 address can be specied.
8. Under User Name, enter a user name.
You can enter up to 32 alphanumeric characters. The following special characters
are not allowed: ", \, ;, :, ,, *, ?, <, >, |, /, ^, &, and %.
Do not use a space either at the beginning or the end.
9. Under Authentication, select whether to Enable or Disable authentication.
If you select Enable, complete the following steps:
a. For Protocol, select an authentication type.
b. For Password, enter a password.
10. Under Encryption, select whether to Enable or Disable encryption.
Note: If you select Disable for Authentication, Encryption is
automatically disabled.
If you select Enable, complete the following steps:
a. For Protocol, select an encryption type.
b. For Key, enter a key.
c. For Re-enter Key, enter the same key for conrmation.
11. Click OK.
The IP address and user you entered are added to the Registered Sending Trap
Settings table.
Adding trap
notication for SNMP v3
Chapter 4: Setting SNMP
Hitachi Alert Notication Guide for VSP5000 Series 26