Error Description Corrective action
noError (0) Normal N/A
noSuchName
(2)
There are no MIB objects that are
required. (Not supported.)
The GETNEXT REQUEST command
that is specied for the following
object identier of the last supported
MIB object is received.
Verify that the name of the
requested object is correct.
SET REQUEST is received. SET REQUEST operation is
not supported.
genErr (5) Error occurred for other reasons. Retry the operation.
Component status information from SNMP Manager
You can obtain the status information of certain storage system components from the
SNMP Manager.
The following table lists the components for which the status can be obtained.
Area Component name
Storage System Processors
BUS
Cache
Shared memory
Power supplies
Batteries
Fans
Others
Disk Unit Power supplies
Fans
Environments
Drives
Component status information from SNMP Manager
Chapter 6: SNMP overview
Hitachi Alert Notication Guide for VSP5000 Series 41