EasyManuals Logo

HITEC ECLIPSE 7 User Manual

HITEC ECLIPSE 7
105 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
Aircraft
(ACRO)
Section
– 29 –
TIME-
Timer Function Setup
The timer function is helpful for keeping track of flight duration, engine run time, or other
things that need to be monitored during flight. You can set up the timer to count down from
anywhere from 0 to 60 minutes.
If you select a time from 1 to 60 minutes, the timer will count down the number of
minutes selected when you first press the Start/Stop button. You may stop it at any time by
pressing the Start/Stop button a second time. Beginning the last 14 seconds of the selected time,
the system will beep every second to tell you the time has elapsed.
If you wish to reset the timer, just press the Off button, it will then be changed to display
mode. You may then press the Start/Stop button to reset it and count down again, whenever you
like.
If you select 0 minutes, the timer acts like a stopwatch and counts upwards.
Setting up the Eclipse Timer
1. With the transmitter switched off, turn on your transmitter while pressing both of the two
Edit
keys (the two keys on the far left). The model select (M.SEL) menu will be displayed.
2. Press the
Up or Down
arrow key until you get into the Timer (TIME) menu. You’ll see a
display with the word “TIME flashing on and off. (If you’re already in the setup menus, you
can just press the
Up
or
Down
arrow key to get here.)
TIME 10
421 3 567
MODEL
3. To change the number of minutes shown, press the +
Increase
and
Decrease
Data
keys until
you see the amount you desire. You may select from 0 to 60 minutes.
4. Press the
Up
or
Down
arrow keys to get to another setup menu, or switch power off.
5. Switch power back on. You may now set up the details of your model in the Edit mode.
REST
— Data Reset
The Reset function is used to clear out an existing set of model data within a single model
memory, the current one. This function resets all data to the factory default values, and may be
used to get a “fresh start” so that you may be begin with a clear memory before you input new
model settings into a memory that had been used for another model.
Resetting the memory
1. With the transmitter switched off, turn on your transmitter while pressing both of the two
Edit
keys (the two keys on the far left). The model select (M.SEL) menu will be displayed.

Table of Contents

Other manuals for HITEC ECLIPSE 7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HITEC ECLIPSE 7 and is the answer not in the manual?

HITEC ECLIPSE 7 Specifications

General IconGeneral
BrandHITEC
ModelECLIPSE 7
CategoryRemote Control
LanguageEnglish

Related product manuals