TM-258 267 Page 34 Handler 140
AGND
AGND
AGND
AGND
+ +
3
2
1
A1
16
RC2
15
RC2
14
RC2
13
RC2
+29V
3
RC2
1
RC2
2
RC2
12
RC2
10
RC2
9
RC2
11
RC2
C5
C4
2
3
1
Q3
R16
R13 R14
R15
R7
1%
R4
R2
R18
R17
+29V
R12
+30V
PTC2
C3
4
8
A1
C2C1
3
2
1
Q2
D6
D7
D14
D9
D10
D12
D8 D5
NC
1
4
3
CR2
52
CR2
12
CR1
+30V +29V
D13
Figure 9-3. Circuit Diagram For 115 VAC Model Control Board PC1
Eff w/MC370275Y And Following

Other manuals for Hobart Handler 140

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hobart Handler 140 and is the answer not in the manual?

Hobart Handler 140 Specifications

General IconGeneral
Input Voltage115V
Welding Amperage Range25-140 A
Duty Cycle20% @ 90A
Wire Feed Speed Range40-700 IPM
Weldable MaterialsMild Steel, Stainless Steel, Aluminum
Weight57 lbs
ProcessesMIG (GMAW), Flux-Cored (FCAW)
Input Current20A
Welding Thickness24 ga. - 1/4 in.
Input PhaseSingle Phase
Maximum Open Circuit Voltage28V
Wire Size Range0.023 - 0.035 in