EasyManuals Logo

Honeywell Galaxy 3-48C Installation Manual

Honeywell Galaxy 3-48C
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #59 background imageLoading...
Page #59 background image
Galaxy 3 Series Installation Manual
5-1
Section 5: Door Control Module - MAX
3
Introduction
The MAX
3
is a proximity reader access control device for a single door, which can also be used for setting
and unsetting of your alarm control panel. The MAX
3
can be configured in one of two ways:
Standalone
In this configuration the MAX
3
can be used for either door control or alarm system set/unset control, by either
connecting the internal relay output to a door lock, external relay or into the keyswitch zone of the alarm
system. When in standalone mode the MAX
3
is programmed and operated using the MAX
3
proximity cards
or tags.The proximity cards and tags each have unique ID numbers and must be identified to the MAX
3
before being used to operate the system. The MAX
3
memory can store up to 999 ID numbers, including at
least three reserved for Masters. Once programmed, the ID number of the tags and cards are stored indefi-
nitely in the MAX
3
memory until voided (removed) or erased. Removing power from the MAX
3
does not
erase the programming memory.
Note : The MAX
3
defaults to standalone mode. It can be configured to on-line mode directly from and of the
Galaxy 3 Series control panels.
On-line
The MAX
3
can operate in on-line mode, with the Galaxy 3 Series control panel range, as a completely inte-
grated module on the system. In this configuration the MAX
3
can be used for both door control and alarm
system set/unset control with complete user traceability stored within the Galaxy control panel.
For detailed instructions on how to programme the MAX
3
onto the system in on-line mode refer to Galaxy 3
Series Programming Manual IP1-0033, Option 63.2=MAX.
Installing the MAX
3
MAX
3
Pack
Your Max
3
pack contains the following:
• Max
3
proximity reader *
• Max
3
drilling template
• Max
3
installation instructions
• Surge suppressor
* The MAX
3
is supplied with 3 metres of 12
wire E111235 AWG cable which is fixed and
sealed through a keyhole opening on the rear
surface of the MAX
3
.
Mounting the MAX
3
To mount the MAX
3
use the step by step
diagrams provided with the drilling template.
The drilling template should be used as an aid
to locate the holes required to secure the
MAX
3
and insert the connection cable.
The MAX
3
comes with an infra red lid tamper.
The tamper is activated when the lid is re-
moved from the MAX
3
unit.
MAX
3

Table of Contents

Other manuals for Honeywell Galaxy 3-48C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy 3-48C and is the answer not in the manual?

Honeywell Galaxy 3-48C Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy 3-48C
CategorySecurity System
LanguageEnglish

Related product manuals