Connecting devices (binding)
20
Binding room setpoint generators/sensors HCW82/
HCF82 with the underfloor heating controller  
Setting the underfloor heating 
controller to the binding mode
 
1
 
Press and hold the installation 
button   on the underfloor heating 
controller for 2 seconds.
 The  LED lights up. The LED 
of zone 1 flashes green.
Binding
 
  Press the installation button   at the 
underfloor heating controller again until 
the red LED of the desired zone flashes.
 
3
 
Press the bind button at 
the HCW82/HCF82.
 
 
The HCW82 transmits the room 
setpoint temperature (offset) and the 
measured room temperature. The HCF82 
transmits only the room temperature 
to the underfloor heating controller. 
  The LED of the selected zone at 
the underfloor heating controller 
lights continuously red.
 
 
The course is the same at the 
HCW82 and HCF82, however 
only the room temperature 
is transferred at HCF82.
!
Binding the room temperature selector T87RF 
with the underfloor heating controller
Setting the underfloor heating 
controller to the binding mode
 
1
 
Press and hold the installation 
button   on the underfloor heating 
controller for 2 seconds.
  The LED   lights up. The LED 
of zone 1 flashes green.
Binding
 
  Keep the left-hand field below the display 
pressed for approx. 10 seconds.  
bo flashes.
 
  Turn the upper part clockwise 
until Hc is displayed.
 
4
  Press the left-hand field below the display 
briefly.  
 flashes several times.
  The LED of the selected zone at 
the underfloor heating controller 
lights continuously red.
Binding the underfloor heating controller without time program – 
continued
123
+-
10 SECONDS